Dynamic Mechanical Analysis

Dynamic Mechanical Analysis (DMA) The DMA Mode adds a new dimension for testing of solid and soft-solid materials. DescriptionSpecifications & FeaturesApplications Dynamic Mechanical Analysis (DMA) The DMA Mode adds a new dimension for testing of solid and soft-solid materials. Now in addition to the most sensitive and accurate rotational shear measurements, the Discovery Hybrid Rheometer…

STA 504

STA 504 Simultaneous Thermal Analyzer The STA504 provides simultaneous measurement of weight change (TGA) and heat flow (DSC) on a sample from -160 to 1650˚C.   OverviewSpecificationsInstrument design The STA504 provides simultaneous measurement of weight change (TGA) and heat flow (DSC) on a sample from -160 to 1650˚C. The STA504 features a vertical balance design…

DXF 500

The Discovery Xenon Flash (DXF) source module employs a High Speed Xenon-pulse Delivery source (HSXD) which has considerably higher efficiency, lower costs and less maintenance than equivalent systems. A reflective optic configuration of our design effectively harnesses the power of a Xenon flash tube and, with the aid of proprietary wave guides, delivers it to the specimen inside the Environmental Module. DXF 500 produces a pulse width of 400 μs to 600 μs and uniformly concentrates the power from the flash source directly on the entire face of the specimen. Due to this optimized optical arrangement and the broad light spectrum, specimens as large as 25 mm in diameter can be illuminated with sufficient energy to make a high-accuracy measurement. The use of large samples diminishes errors associated with inhomogeneity and permits representative measurements of poorly dispersed composites.

DXF 200

The Discovery Xenon Flash DXF 200 employs a High Speed Xenon-pulse Delivery source (HSXD) with considerably lower cost and less maintenance than a laser and generates equivalent results. A reflective optic configuration of our design effectively harnesses the power of a Xenon flash tube and, with the aid of proprietary wave guides, delivers it to the specimen inside the Environmental Module. DXF 200 produces a pulse width that is shorter (400 μs to 600 μs) than many commercial laser-based systems, while uniformly concentrating sufficient power from the flash source directly on the entire face of the specimen. Due to this optimized optical arrangement and the broad light spectrum, specimens as large as 25 mm in diameter can be illuminated with sufficient energy to make a high-accuracy measurement. The use of large samples diminishes errors associated with inhomogeneity and permits representative measurements of poorly dispersed composites.

DLF 1600

Discovery Laser Flash DLF 1600’s source module is a freestanding unit employing a custom Class 1 35 J Nd:Glass laser pulse source. It provides a collimated, monochromatic energy pulse to specimens heated up to the temperature of 1600°C. The laser radiation is delivered via a proprietary fiber optic delivery wand which ensures a 99% homogenized laser pulse. Leading to much more accurate measurements than any direct firing laser pulse instruments. The laser source produces a 300 µs to 400 µs pulse width.

Starch Pasting Cell

Starch Pasting Cell (SPC) Provides a more accurate and powerful tool to characterize the gelatinization of raw and modified starch products, as well as the properties of the starch gels. DescriptionTechnologyFeaturesApplications Starch Pasting Cell (SPC) The Starch Pasting Cell (SPC) provides a more accurate and powerful tool to characterize the gelatinization of raw and modified…

Immobilization Cell

Immobilization Cell Permits the characterization of drying, retention, and immobilization kinetics of paints, coatings and slurries. DescriptionTechnologyFeaturesApplications Immobilization cell The new Immobilization Cell Accessory for the Discovery Hybrid Rheometer permits the characterization of drying, retention, and immobilization kinetics of paints, coatings and slurries. Solvent is dewatered from the sample through a paper substrate affixed to…

Dielectric Measurement

Dielectric Measurement Extends material characterization capabilities by providing an additional technique similar to dynamic mechanical. DescriptionTechnologyFeaturesApplications Dielectric Measurement The Dielectric Accessory, available for all DHR models, extends material characterization capabilities by providing an additional technique similar to dynamic mechanical. In dielectric analysis, an oscillation electrical field (AC Field) is used as opposed to mechanical force…

UV Curing Accessories

UV Curing Accessory uses a light guide and reflecting mirror assembly to transfer UV radiation from a high-pressure mercury light source. DescriptionTechnologyApplications UV Curing Accessories UV-curable materials are widely used for coatings, adhesives, and inks. When these materials are exposed to UV radiation, a fast cross-linking reaction occurs, typically within less than a second to…