Discover The Discovery DSC
https://www.youtube.com/watch?v=ulXbA3ygoOA&list=PLC69993381001BF6B&index=2
https://www.youtube.com/watch?v=ulXbA3ygoOA&list=PLC69993381001BF6B&index=2
Dile Holton, Ph.D.: Characterization of Drug Binding Activity and Biopharmaceutical Stability This webinar is focused on enthalpy screening, a new and recently published ITC technique that is showing promise for rapidly and accurately characterizing the binding enthalpy of new drugs or biotherapeutics. Rapid and accurate characterization of biopharmaceuticals is essential for the early selection of…
DetailsDIL 832 High Resolution True Differential Horizontal Push Rod Dilatometer High sensitivity optical encoder and TA exclusive True Differential technology for the most demanding R&D laboratories . << View all 830 Series Dilatometers DescriptionSpecificationsMeasurement PrincipleApplications DIL 832 features an impressive array of unique technologies and capabilities that make of it the ideal tool in any R&D…
DetailsDIL 831 High Resolution Horizontal Push Rod Dilatometer High sensitivity optical encoder and motorized furnace in the best performing single sample push rod dilatometer available. << View all 830 Series Dilatometers DescriptionSpecificationsMeasurement PrincipleApplications Packed with new automated features, the DIL 831 features the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and…
DetailsThe 820 Series operate in a vertical orientation, making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise difficult to be analyzed on classic dilatometers with horizontal design.
Available in two different models (DIL 821 and DIL 822), both the units feature the new optical encoder with 1nm resolution. That when combined with the True Differential of the DIL822, the result is simply the best possible sensitivity and CTE accuracy on the market.
DetailsThe 820HT Series operates up to high temperatures in a vertical orientation , making it uniquely set up for the analysis of sintering, studies in Rate Controlled Sintering (RCS) mode and the determination of dilatometric parameters of samples otherwise Impossible to be correctly analyzed on classic dilatometers with horizontal design.
Available in two different models (DIL 821HT and DIL 822HT), both the units feature the new optical encoder with 1nm resolution. That when combined with the True Differential of the DIL822HT, the result is simply the best possible sensitivity and CTE accuracy in the high temperatures segment.
DetailsThis optical dilatometric measurement method used in DIL 806 is an absolute process, entirely independent of any possible expansion or contraction of the instrument. Consequently, measured results do not need to be corrected or calibrated for different temperature programs. Coupled with the fast response of the DIL806 furnace, this makes the system particular well-suited for the analysis of dynamic processes that involve multiple temperature steps and dynamic heating rates.
Details