View allAerospaceArchiveARES G2 AccessoriesARES RheometerAutomated Density TesterAutomated Hardness TesterAutomotiveBasic CharacterizationBatteries & Battery MaterialsBendingBioDynamic InstrumentsBiomaterials and TissuesBiomaterials and TissuesBiopharmaceuticalsBiosensorsBlogBone CementCardiovascularCardiovascular (Tissue Engineering)cardiovascular instrumentsCardiovascular Medical DevicesCell Biology and Cell-BiomaterialChewing Simulator for WearCleanroomComponent Fatigue (rubber)Components (Electronics)Components (Polymers)CreepDental ImplantsDental Implants and MaterialsDental MaterialsDHR AccessoriesDifferential Scanning CalorimetersDifferential Scanning CalorimetryDIL 830 SeriesDilatometersDilatometry videosDilatometryDiscovery Hybrid RheometersDrug DeliveryDynamic Mechanical Analysis (DMA)Dynamic Mechanical Analyzers (DMA)Dynamic Mechanical Analyzers (Rheology)Dynamic Mechanical Analyzers (Thermal Analysis)ElectroForceElectroforceElectroforceElectronic Materials & ProductsElectronicsEnvironmentalEyeFatigue and DurabilityFlash Diffusivity SystemsFracture FixationFracture MechanicsGeneral Biomaterials CharacterizationGeneral Scaffold CharacterizationGeneralGuarded heat flow meterGuarded Hot PlateHeart Valve Durability TestingHeating MicroscopesHorizontal DilatometersHot/ColdIndentationInsulation & Building MaterialsISOIsothermal CalorimetryIsothermal Titration CalorimetryJoint ReplacementsLaser FlashLoad frame systemsMaterial CharacterizationMaterials TestingMaterials Testing (Electronics)Materials Testing (Polymers)Materials Testing (rubber)Medical Device TestingMedicalMetalsMicrocalorimetry videosMicrocalorimetryMicrocalorimetryMicrocalorimetryMooney ViscometerMoving Die RheometerMulti-specimen Fatigue LifeMulti-specimen TestingMultiaxial TestingNeuromodulationNews & InfoOptical DilatometersOptical FleximeterOrthopaedic and MusculoskeletalOrthopaedic and MusculoskeletalOrthopaedic Devices and NeuromodulationOther TissuesOther Tissues and OrgansPharmaceuticalsPill TestingPolymers, Plastics and CompositesProduct videosProductsPromotionsPulsatileQuenching DilatometersQuick start guidesRegenerative MedicineResearch and Design ValidationResearch (rubber)Rheology videosRheologyRheologyRheology AccessoryRheologyRotational ViscometerRubberRubber AccessoriesRubber Process AnalyzersRubberRubber TestingSaline BathsScaffold BiodegradationService VideosShearSimultaneous Thermal AnalyzerSkin and Other OrgansspineStent Durability TestingSterileStress RelaxationTech TipsTension/CompressionTestbench and Planar Biaxial systemsThermal Analysis videosThermal AnalysisThermal AnalysisThermal ApplicationsThermal Conductivity MeterThermal ConductivityThermogravimetric AnalysisThermomechanical AnalyzersTire & rubberTissue EngineeringTissue EngineeringTissue/Organ BathsTorsionTrade shows and eventsUncategorizedVapor Sorption AnalysisVertical DilatometersVideosDilatometryWebinarsMicrocalorimetryRheologyRubberThermal AnalysisXenon Flash

Nano DSC

The Nano DSC differential scanning calorimeter is designed to characterize the molecular stability of dilute in-solution biomolecules. The Nano DSC obtains data using less sample than competitive designs. Solid-state thermoelectric elements are used to precisely control temperature and a built-in precision linear actuator maintains constant or controlled variable pressure in the cell. Automated, unattended continuous operation with increased sample throughput is achieved with the optional Nano DSC Autosampler.

Details

MV one

The MV one Mooney Viscometer incorporates the latest measurement technology for the traditional Mooney viscosity, Mooney scorch, and stress relaxation measurement in the rubber industry. The MV one is a fully featured instrument configured for standard viscosity, scorch and stress relaxation (linear, logarithmic, ISO, Mooney Stress-relaxation Rate) testing of rubber compounds under isothermal test conditions at constant speed of 2 rpm. An optional continuously variable motor mode allows tests over a speed range of 0.1 to 10 rpm. The MV one Mooney Viscometer is equipped with low mass rotors that meet all relevant ASTM, ISO, and DIN standards. All TA Instruments rubber testing instruments are constructed on ultra-rigid test frames and include direct drive motors, precision temperature control and the powerful and intuitive Scarabaeus Control and Analysis Software.

Details

Multicell DSC

The MC DSC is a versatile, multi-purpose calorimeter that combines microwatt sensitivity with increased sample throughput. Compared with a single sample DSC, the three removable, reusable sample ampoules and one reference ampoule in the MC DSC increases sample throughput and ensures high precision and unmatched reproducibility. The wide mouth, removable ampoules and additional sample manipulation allow study of materials that are physically not compatible with other calorimeters.

Details

Multi-Specimen Fatigue

To reduce time and costs for developing fatigue life (s/n) curves for NiTi, CoCr, and SS stent materials and structures, TA ElectroForce has configured multi-specimen test systems utilizing the versatility of the ElectroForce 3200 and 3330 test instruments. Both systems include the enhanced measurement capability of the TA ElectroForce High Accuracy Displacement Sensor. This enables an even wider range of testing by improving low-amplitude displacement measurements, all through a single, easy-to-use displacement channel. The sensor is calibrated to the highest accuracy class, Class A, of ASTM E-2309

Details

MDR one

The MDR one Moving Die Rheometer (MDR) is a reliable, accurate, and easy-to-operate rotorless curemeter perfect for routine and standards-driven testing of rubber curing. The MDR one is configured for measuring curing profiles of rubber compounds under isothermal and non-isothermal test conditions at constant strain and frequency.The MDR one employs sealed biconical dies meeting all relevant ASTM, ISO, and DIN standards.The unique design includes an ultra-rigid test frame, direct drive motor, precision temperature control with optional cooling, available Autosampler, and intuitive Scarabaeus Control and Analysis software making it the ideal platform for QC or R&D environments.

Details

HM 867 Heating Microscope

Result of over twenty years of R&D of optical instruments for the study of the thermo-mechanical behavior of materials, HM 867 makes possible the analysis of samples beyond the limits of classical heating microscopy. Its versatility makes of HM 867 the most innovative tool for both R&D and for the optimization of all the industrial processes that involve thermal cycles.

Adopting state-of-the-art technologies in the field of optical and thermal analysis, it is supplied with Misura 4 Thermal Analysis software, the proven software platform that provides an intuitive interface for instrument control and data handling and features the most thorough and precise image analysis.

Details

Heart Valve Durability

Using proprietary ElectroForce controls and linear motor technology, the DuraPulse Heart Valve Test (HVT) instrument achieves smooth waveform fidelity and precise control for accelerated heart valve durability testing. Automatic feedback control and independent test chambers ensure that established test conditions are maintained throughout the test. The DuraPulse HVT instrument provides testing to the ISO 5840 standard for heart valve durability assessment.

Details

Fox 801

The FOX 801 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Capable to operate both in standalone or PC-controlled configurations, FOX 801 Heat Flow Meter provides rapid and accurate results. The instrument features proprietary thin film heat flux transducers, digital thickness measurements and responsive temperature control. A versatile instrument, it is especially well-suited to measuring slices of cellular plastics.

Details

Fox 600 GHP

FOX 600 GHP is especially well-suited for thermal conductivity measurements at high temperatures, exhibiting unrivaled temperature and dimensional stability. Each of its components include state-of-art technology representing the best available today in advanced materials and electronics.

In a Guarded Hot Plate system a temperature difference (ΔT) is established across a sample of known thickness (L). The thermal conductivity is calculated from the temperature difference across the known thickness and the steady state power (W) per area (A) required to maintain the temperature difference. The Guarded Hot Plate uses a direct measurement of the electrical power supplied to the hot plate rather than heat flow meter signals from a Heat Flux Transducer.

Details

Fox 600

The FOX 600 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Capable to operate both in standalone or PC-controlled configurations, FOX 600 Heat Flow Meter provides rapid and accurate results. The instrument features proprietary thin film heat flux transducers, digital thickness measurements and responsive temperature control. A versatile instrument, it is especially well-suited to measuring slices of cellular plastics.

Details

Fox 50

The FOX 50 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity and provides rapid results in a compact footprint. The instrument is configured with the identical high performance features and proprietary technologies of the larger FOX systems including thin film heat flux transducers, digital thickness measurements, responsive temperature control, plus an integrated contact-resistance correction.

Details