View allAerospaceArchiveARES G2 AccessoriesARES RheometerAutomated Density TesterAutomated Hardness TesterAutomotiveBasic CharacterizationBatteries & Battery MaterialsBendingBioDynamic InstrumentsBiomaterials and TissuesBiomaterials and TissuesBiopharmaceuticalsBiosensorsBlogBone CementCardiovascularCardiovascular (Tissue Engineering)cardiovascular instrumentsCardiovascular Medical DevicesCell Biology and Cell-BiomaterialChewing Simulator for WearCleanroomComponent Fatigue (rubber)Components (Electronics)Components (Polymers)CreepDental ImplantsDental Implants and MaterialsDental MaterialsDHR AccessoriesDifferential Scanning CalorimetersDifferential Scanning CalorimetryDIL 830 SeriesDilatometersDilatometry videosDilatometryDiscovery Hybrid RheometersDrug DeliveryDynamic Mechanical Analysis (DMA)Dynamic Mechanical Analyzers (DMA)Dynamic Mechanical Analyzers (Rheology)Dynamic Mechanical Analyzers (Thermal Analysis)ElectroForceElectroforceElectroforceElectronic Materials & ProductsElectronicsEnvironmentalEyeFatigue and DurabilityFlash Diffusivity SystemsFracture FixationFracture MechanicsGeneral Biomaterials CharacterizationGeneral Scaffold CharacterizationGeneralGuarded heat flow meterGuarded Hot PlateHeart Valve Durability TestingHeating MicroscopesHorizontal DilatometersHot/ColdIndentationInsulation & Building MaterialsISOIsothermal CalorimetryIsothermal Titration CalorimetryJoint ReplacementsLaser FlashLoad frame systemsMaterial CharacterizationMaterials TestingMaterials Testing (Electronics)Materials Testing (Polymers)Materials Testing (rubber)Medical Device TestingMedicalMetalsMicrocalorimetry videosMicrocalorimetryMicrocalorimetryMicrocalorimetryMooney ViscometerMoving Die RheometerMulti-specimen Fatigue LifeMulti-specimen TestingMultiaxial TestingNeuromodulationNews & InfoOptical DilatometersOptical FleximeterOrthopaedic and MusculoskeletalOrthopaedic and MusculoskeletalOrthopaedic Devices and NeuromodulationOther TissuesOther Tissues and OrgansPharmaceuticalsPill TestingPolymers, Plastics and CompositesProduct videosProductsPromotionsPulsatileQuenching DilatometersQuick start guidesRegenerative MedicineResearch and Design ValidationResearch (rubber)Rheology videosRheologyRheologyRheology AccessoryRheologyRotational ViscometerRubberRubber AccessoriesRubber Process AnalyzersRubberRubber TestingSaline BathsScaffold BiodegradationService VideosShearSimultaneous Thermal AnalyzerSkin and Other OrgansspineStent Durability TestingSterileStress RelaxationTech TipsTension/CompressionTestbench and Planar Biaxial systemsThermal Analysis videosThermal AnalysisThermal AnalysisThermal ApplicationsThermal Conductivity MeterThermal ConductivityThermogravimetric AnalysisThermomechanical AnalyzersTire & rubberTissue EngineeringTissue EngineeringTissue/Organ BathsTorsionTrade shows and eventsUncategorizedVapor Sorption AnalysisVertical DilatometersVideosDilatometryWebinarsMicrocalorimetryRheologyRubberThermal AnalysisXenon Flash

Heart Valve Durability

Using proprietary ElectroForce controls and linear motor technology, the DuraPulse Heart Valve Test (HVT) instrument achieves smooth waveform fidelity and precise control for accelerated heart valve durability testing. Automatic feedback control and independent test chambers ensure that established test conditions are maintained throughout the test. The DuraPulse HVT instrument provides testing to the ISO 5840 standard for heart valve durability assessment.

Details

Planar Biaxial

The ElectroForce Planar Biaxial TestBench instrument offers superior control and unparalleled performance in material and soft tissue characterization. Using this instrument, you can assess mechanical anisotropy and stress-strain relationships in samples that range from engineered devices, including wearable sensors and wound repair meshes, to tissues such as skin, pericardium, and heart valve leaflets. This instrument can be configured with either two or four ElectroForce linear motors mounted on a horizontal baseplate and load cell options for each axis of loading

Details

ElectroForce 5500

The ElectroForce 5500 test instrument provides characterization and stimulation capabilities for a variety of synthetic materials such as composites and elastomers, biomaterials, tissue samples, and tissue-engineered constructs. It features a 200 N maximum force.

This test instrument is versatile and can meet the individualized needs of educators and researchers through a variety of fixtures and software options.

Details

ElectroForce 3300

ElectroForce Series II 3300 test instruments are well-suited for a variety of tests that include ASTM and ISO standards for medical devices, materials characterization, and long-term durability tests. The ElectroForce 3300 series includes two test instruments; the ElectroForce 3310 provides 1000 N of maximum force while the ElectroForce 3330 provides 3000N. Both test instruments can perform tests that range from one cycle per day (or static tests) up to 100 Hz Select the force capacity that is appropriate for your testing needs.

Details

ElectroForce 3200

The ElectroForce 3200 Series III test instruments feature a 225 N (450 N optional) maximum force. With the versatility of static to 300 Hz frequency response, the table-top configuration is adaptable to a variety of biomedical research and engineered materials test applications, including torsion testing, creep under dynamic loading and special environments (hot/cold chambers).

Details

ElectroForce 3100

Measuring less than 50.8 cm (20 inches) tall, the ElectroForce 3100 test instrument is the smallest in the ElectroForce product family. The 3100 will fit on a desk or table-top, and it is extremely lab friendly thanks to its practically maintenance-free operation. The 3100 instrument is well-suited for micro-characterization of materials and devices because of its exceptional control resolution up to 22 N static maximum force.

Details

Scarabaeus Software

Scarabaeus Software Instrument Control and Data Analysis The Scarabaeus Software for instrument control and data analysis is a powerful and versatile system for programming experiments, providing quick feedback of results, and managing data from all rubber testing instruments. The Scarabaeus Software was developed with customers from the rubber industry and is designed to meet the…

Details

Sample Cutter

Sample preparation for RPA, MDR, and Mooney instruments is made safe and simple with the VS volumetric sample cutter. This dual-action pneumatic system allows for the preparation of uncured rubber specimens of a user-defined volume. Preparing samples in this well-controlled fashion reduces operational variability, greatly improving overall experimental precision.

The VS comes standard with a closing pressure of 6 bar. The sample is first compressed to the user-prescribed thickness, then cut to the die diameter. The closing pressure, and sample volume are user adjustable. Two handed operation and lateral guards guarantee safe operation at all times.

Details

TAM IV

TAM IV is the most sensitive, stable and flexible microcalorimeter system in the world for directly measuring this universal heat signal and, therefore, the quantitative thermodynamic and kinetic observation of any process. It is a unique microcalorimeter system that is completely modular and combines the highest heat flow sensitivity with unmatched long term temperature stability for measuring many processes that are undetectable by other techniques. A wide range of calorimeter configurations and sample handling systems provide maximum application flexibility and ensure optimum laboratory productivity.

Details

DIL 805A/D Quenching Dilatomers

The DIL805 Series comprises of four models: DIL 805L, DIL 805A are quenching dilatometers, DIL 805A/D is a quenching with the capability to deform the specimen by compression, and DIL 805A/D/T that can also stretch it in tension mode.

All four instruments are fully automated, self-contained units used to measure dimensional changes under extreme conditions of controlled heating and cooling.

Details